Business Network California
Companies:114,335
Products and Services:5,136
Articles and publications:2,475
Tenders & Vacancies:595

Bay Cities Pyrotector Inc
Information may not be reliable

Bay Cities Pyrotector is comprised of individuals whose years of experience in the fire service industry led them to create a locally owned,
Address1435 Park Ave Emeryville, CA 94608-3519
Phone(510) 450-7760
Websitewww.baycitiesfire.com
Web-Based Code Compliant Inspection Reports

HALON 1301 Valve Rebuilding
HALON 1301 Recycling Services, Nitrogen Separation to MIL Spec
FM200 Cylinder Recharging
FM200 Valve Rebuilding
FM200 Recycling Services, Nitrogen Separation to MIL Spec
CO2 System Cylinder Recharging

Fire Alarm Systems: Design, Testing, Repair, and Installation

CO2 Systems: Testing, Repairs and Recharging

Restaurant Hood Suppression and HAZMAT Systems: Testing

Paint Booth Suppression Systems: Testing and Installation

Exit Signs: Testing, Sales and Installation

Incandescent exit signs are inexpensive, and can use a wide variety and number of lamps. However, incandescent lamps are very inefficient and lose a lot of their energy to heat instead of useful light.
Standard incandescent lamps have a relatively short life, around 1,000 hours on average. Some incandescent lamps specifically designed for exit signs have longer lamp lives up to 7,000 hours.
To increase lamp life, some facility managers install lamps rated for higher voltage, which greatly increases lamp life but doesnt save energy.

Fluorescent exit lights are also inexpensive, typically using two 11- or 7-watt lamps. One lamp is illuminated until it burns out, after which the other lamp is illuminated which saves on maintenance cost.
A fluorescent lamp has an expected life of about 10,000 hours, significantly reducing maintenance expenses.
LED (Light Emitting Diode):
LED exit signs are more expensive than incandescent and fluorescent exit signs, but that cost gap has been closing quickly. LEDs are the most efficient powered exit signs on the market.
LED exit lights are typically designed with strips of LEDs where the light is reflected out of the face of the exit sign or the LEDs can be placed directly behind the face of the exit sign for illumination.

OSHA Regulations Regarding Exit Lighting

Each exit route must be adequately lighted so that an employee with normal vision can see along the exit route. 1910.37(b)(1)

Each exit must be clearly visible and marked by a sign reading "Exit." 1910.37(b)(2)

Each exit route door must be free of decorations or signs that obscure the visibility of the exit route door. 1910.37(b)(3)

If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. 1910.37(b)(4)

Each doorway or passage along an exit access that could be mistaken for an exit (such as a closet) must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use. 1910.37(b)(5)

Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted. 1910.37(b)(6)

Each exit sign must have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three-fourths of an inch (1.9 cm) wide. 1910.37(b)(7)

Emergency Lighting: Testing and Installation

Sprinkler Systems: Inspection, Testing, Repair, and Installation

Standpipe/Sprinkler Systems: 5 year Testing, Maintenance, and Repair
Title 19 - NFPA 25 Compliance

Fire Pump: Testing, Repairs and Maintenance

Fire Hose: Testing, Re-coupling, and Sales

SCBA: Pressure Testing and Eddy Current Testing PSI Certified

SCUBA: Pressure Testing and Eddy Current Testing PSI Certified

Fire Extinguisher: Sales, Service and Testing

OSHA Compliant Employee Extinguisher Training

Revised 11.22.08 Bay Cities Pyrotector Inc.

Branches and additional offices:
(925) 944-1500 Walnut Creek, CA 94596
(415) 626-0400 San Francisco, CA 94103
Rating:

Related items:

All Smogs Test & Auto Repair
Information may not be reliable
Make your smog check and auto repair easy, call us, All Smogs! We have over 30 years of experience serving the Tri-Valley and East Bay. We are car repair experts. Plus we are active in the community.
  • 7034 Village Pkwy, Dublin, CA, 94568
  • +1 (925) 828-7277
Bay Area Disc Center
Information may not be reliable
At Bay Area Disc Centers, we treat every patient as a partner in the process of healing their conditions and helping them regain normal activities and a pain-free lifestyle.
  • 177 Bovet Rd. #150
  • +1 (408) 340-6484
Avanti Pools Inc.
Information may not be reliable
Avanti Pools, Inc has been a Los Angeles pools builder for over twelve years now, but our designer experts have been in the business for over 25 years. This gives you the ability to trust us.
  • 8138 Orion Ave, Van Nuys
  • +1 (818) 501-3759
S S L Industries Inc
Information may not be reliable
SSL Industries, Inc. and its multi-faceted groups, has strived to provide our customers with the best services available.
  • 4783 Village Green Dr El Dorado Hills, CA 95762-7675
  • (916) 351-1060
Drywall Service Panorama City
Information may not be reliable
Drywall finishing, Drywall contractors, Dry Wall Contractor, Drywall lift, Drywall Company, Scaffolding, plaster, Drywall Plastering, Drywall
  • 14527 Plummer St #70, Panorama City, CA 91402
  • 1 (818) 539-1968
×